Automatic Balances for Pipettes Calibration

AP-12.5Y Automatic Device for Multichannel Pipette Calibration
This image is for reference only.
AP-12.5Y Automatic Device for Multichannel Pipette CalibrationAP-12.5Y Automatic Device for Multichannel Pipette Calibration
close Exit
This image is for reference only.
AP-12.5Y Automatic Device for Multichannel Pipette CalibrationAP-12.5Y Automatic Device for Multichannel Pipette Calibration
Availability:
To order
Estimated shipping date :
15 working days

Need it urgently? Call us to check real-time stock availability: +44 (0)1625 569569

Price:
36253.20
 GBP
with 20% VAT, shipping cost not included
Choose a variant:
AP-12.5Y Automatic Device for Multichannel Pipette Calibrationkeyboard_arrow_down
  • AP-12.1.5Y Automatic Device for Multichannel Pipette Calibration
    Max: 18g | d: 1µg
  • AP-12.5Y Automatic Device for Multichannel Pipette Calibration
    Max: 52g | d: 0,01mg
  • AP-12/12.5Y Automatic Device for Multichannel Pipette Calibration
    Max: 25 g (na każdy kanał) | d: 0,01mg

Pcs.

Add to basket
We are near you.
We have been manufacturing weighing devices since 1984.

RADWAG UK Limited
16 Macon Court, Herald Drive, Crewe, CW1 6EA
+44 01625 569569


Delivery only on the territory of United Kingdom
Optional paid installation and training service available - please contact us for details and pricing.
Code:
WL-101-0416
CE
CE
1 year warranty
1 year warranty

Datasheet

Maximum capacity [Max]
52 g
Readability [d]
0,01 mg
Tare range
-52 g
Minimum weight (USP)
10 mg
Minimum weight (U=1%, k=2)
1 mg
Standard repeatability [Max]
10 µg
Standard repeatability [5% Max]
5 µg
Linearity
±0,03 mg
Stabilization time
4 s
Adjustment
internal (automatic)
Typical measurement time for a 12-channel pipette with constant volume, <br>according to ISO 8655 (for d=10 µg)*
under 20 minutes
Typical measurement time for a 12-channel pipette with variable volume, <br>according to ISO 8655 (for d=10µg)*
under 60 minutes
Maximum volume
12 ml
Display
10″ graphic colour touchscreen
Communication interface
2×USB-A, USB-C, RS 232 (COM3), HDMI, Ethernet, Wi-Fi®, Hotspot
Power supply
Adapter: 100 – 240V AC 50/60Hz 1A Max; 15V DC 2,4A
Device: 12 – 15V DC 1,6A max; 10 – 29W*
Operating temperature
+10 – +40 °C
Operating temperature change rate
±0,3 °C / 1 h (±1 °C / 8 h)
Relative humidity
20% – 80%
Relative humidity change rate
±1% / h (±4% / 8 h)
Weighing pan dimensions
intended + ø26 mm for calibration
Packaging dimensions W x D x H
605×560×775 mm
Net weight
17 kg
Gross weight
30 kg

Overview


 

AP-12.5Y Automatic Device for Multichannel Pipette Calibration

 
 

The AP-12.5Ycan be used for multichannel pipette tests with nominal volumes below 20 µl. The device features a readability [d] of 0.01 mg and can calibrate up to 12-channel fixed-volume and variable-volume pipettes.

 

Because the pipette calibration on the AP-12.5Y is fully automatic, it is four times faster. The calibration procedure for a 12-channel pipette takes less than 20 minutes, not six hours, on this instrument.

 

When purchasing the AP-12.5Y, you get:

  • two calibrated sensors: THB S and THB W,
  • two weighing pans: standard, and for balance test and calibration,
  • two pumps: a single-channel pump and a four-channel pump

 

The ergonomic design of the AP-12.5Y makes it possible to empty weighing vessels, and their overfilling is signalled by Ambient Light. When calibrating a multichannel pipette, a four-channel pump is used to simultaneously remove water from four vessels, greatly reducing the time required for pipette calibration.

 

After emptying a 12-channel pipette, the AP-12.5Y checks all channels in a single cycle. In addition to a database of pipette calibration reports, the AP-12.5Y includes a database of pipettes that is editable and contains maximum permissible error values according to ISO 8655. The report database, in turn, contains measurements and error values calculated for individual points and volumes. The user determines the format and content of the reports.

 

The AP-12.5Y monitors the ambient conditions using calibrated sensors: THB S (ambient conditions measurement) and THB W (liquid temperature measurement), in accordance with ISO 8655. To calibrate the device with mass standards, the weighing pan must be replaced with a pan dedicated to checking and calibrating the balance (both are included in the standard equipment).

 

The AP-12.5Y can calibrate not only 12-channel pipettes, but also single-channel pipettes.